Home Uncategorized Ballu Air Conditioner Error Code

Ballu Air Conditioner Error Code

0
Ballu Air Conditioner Error Code
on page optimization

Ballu air conditioner error code

Ballu Air Conditioner Error Code

Ballu Air Conditioner Error Code


Ballu air conditioner error code,MFS2 series


E1, E2, E3, E4 – Temperature sensor (internal or external unit, condenser temperature, evaporator temperature) is small or broken.
E6 – External unit safety tripped
E8 – Closed Electrostatic Filter
P4 – Error on Evaporator Sensor, Very Low / High Temperature (compressor stops automatically)
P5 – Error on capacitor sensor, very low / high temperature (compressor stops automatically)
P6 – Defrost or delay temperature of internal heat exchanger


Ballu air conditioner error code,BSC series error codes; BV; BR

E1 – Internal Air Temperature Sensor Error
E2 – Evaporator Temperature Sensor Error
E5-system entered protection mode by mistake of external unit
E6 – Indoor unit fan engine error
E1, E2, E3, E4 – Temperature sensor (internal or external unit, condenser temperature, evaporator temperature) is small or broken.
E6 – External unit safety tripped
E8 – Closed Electrostatic Filter
P4 – Error on Evaporator Sensor, Very Low / High Temperature (compressor stops automatically)
P5 – Error on capacitor sensor, very low / high temperature (compressor stops automatically)
P6 – Defrost or delay temperature of internal heat exchanger


BSC series error codes; BV; BR

E1 – Internal Air Temperature Sensor Error
E2 – Evaporator Temperature Sensor Error
E5-system entered protection mode by mistake of external unit
E6 – Indoor unit fan engine error


Description of error code LED on panel indication on digital display

BCAL model 3-phase BCFA and BDA model 3-phase
The error of switching indoor and outdoor units breaks 5 flashes – 2 seconds. F1
Wired remote control switching error – E5
Break down the drainage system error 4 flashes – 2 seconds. E4
External unit protection – Phase sequence error breaks 6 flashes – 2 seconds. E6
Protection of external unit – high temperature of injection (condensation) 10 flashes – brake 2 seconds ea
Protection of the outdoor unit – high pressure sensor was triggered 9 lashes – 2 seconds of break. E9
Protection of external unit – low pressure sensor was triggered 9 lashes – 2 seconds break. E9
Open or short-circuit the indoor temperature air temperature sensor with a periodicity of 2 seconds. E 1
Indoor unit temperature sensor 3 Breakdown or short circuit of flashing – 2 seconds. E3
Open or short circuit of outdoor unit temperature sensor 2 – break 2 seconds E2
Open or short circuit of outdoor unit air temperature sensor 7 – Flash 2 brake. E7
Outdoor unit temperature sensors break 8K open or short circuit – 2 seconds. E8
Insufficient amount of fron in the system. 11 flashes – 2 second break